Our cooling systems are powerful enough to ensure your power needs never exceed our cooling ability.

At Aegis Data, we have adopted Direct Fresh Air Cooling (DFAC), one of the most efficient methods for cooling data centres. This enables our customers to house their racks contiguously without the requirement to segregate high density platforms. Additionally, DFAC maximises our customer’s footprint – without increases in operating and cooling costs – helping to lower their total cost of ownership.

We guarantee efficiency, offering an exceptional ultra-low design Power Usage Effectiveness (PUE) of 1.13 and a contracted PUE of 1.2.

"In today’s climate, both new and existing technologies continue to grow and innovate in response to customer demand. But running parallel with this technological momentum is the pressure placed on the data centre to ensure these technology trends reach their full potential"

We are incredibly conscious of limiting our energy consumption and playing an involved role towards a greener industry. As a result, our facility has been designed to adhere to the EU Code of Conduct for Data Centre Efficiency and combined with our effective fresh air cooling systems, delivering an ultra-efficient environment and passing these costs efficiencies directly to our customers.

Aegis Data's Direct Fresh Air Cooling (DFAC) system. Cool ambient air is drawn into the DC, filtered and dynamically mixed to ensure ultimatum humidity and temperature for the data halls at all time.  We are able to utilise this fresh air cooling 365 days a year.  This produces a dramatically improved energy consumption compared to traditional closed looped cooling systems.

Aegis Data's Direct Fresh Air Cooling (DFAC) system. Cool ambient air is drawn into the DC, filtered and dynamically mixed to ensure ultimatum humidity and temperature for the data halls at all time. We are able to utilise this fresh air cooling 365 days a year. This produces a dramatically improved energy consumption compared to traditional closed looped cooling systems.

Technical Specifications

  • Direct Fresh Air Cooling
  • Ultra-low contracted PUE of 1.2
  • Average supply temperature 20ºC – 25ºC ± 2°C
  • N+1 Cooling infrastructure delivered under floor with (CRAC) units
  • Heat rejection installed to take air away from white space
  • Moisture detection and control sensors
  • Back up Direct Exchange system for ancillary cooling and full Tier 3 aligned resilient back up on very hot days
  • Full N+1 DX back up cooling infrastructure

Download the DFAC specifications here